Quick tech specs
- Power distribution unit (rack-mountable)
- 8.6 kW
- RS-232, Ethernet 10/100/1000
- output connectors: 36
- 10 ft
- black
- AC 208 V
- 3-phase
- input: NEMA L15-30
- 0U
- North America
Know your gear
CPI's Monitored Pro eConnect PDU connects you to your evolving enterprise data center. Whether you need to connect a few pieces of equipment or need to support high density computing with multiple blade servers in every cabinet, Monitored Pro eConnect PDU provides reliable power distribution with remote per-outlet power monitoring.
Choose the Monitored Pro eConnect PDU when you need to know how much power each piece of equipment is using. Monitored Pro eConnect PDU provides continuous remote voltage, current, and power (kW) and energy (kilowatt-hour) monitoring for each outlet on the PDU. You can also use the built-in web interface to group outlets and see combined current use for multiple outlets - an excellent way to measure power use by different types of equipment attached to the PDU.
An easy to read central display provides detailed information about total power usage by attached equipment. The PDU has an Ethernet connection, an external connection for two environmental probes and two connections for linking PDUs together. You can enter the IP address using the local display for quick attachment to the network. Then, access the PDU remotely using a web browser for detailed measurements and to set upper and lower threshold alarms for power, temperature and humidity. Link up to 20 PDUs together to share a single Ethernet connection and IP address. The web browser lets you easily click between linked PDUs and any alarms are summarized on a separate tab. You can also forward email alarm notifications to staff and log data and events to keep a record of power use and alarms.
The PDU features a low profile design, has universal tool-less mounting and can be confidently deployed in cabinets with CPI vertical exhaust ducts or in hot aisle containment applications in ambient air temperatures up to 149°F (65°C).
Choose the Monitored Pro eConnect PDU when you need to know how much power each piece of equipment is using. Monitored Pro eConnect PDU provides continuous remote voltage, current, and power (kW) and energy (kilowatt-hour) monitoring for each outlet on the PDU. You can also use the built-in web interface to group outlets and see combined current use for multiple outlets - an excellent way to measure power use by different types of equipment attached to the PDU.
An easy to read central display provides detailed information about total power usage by attached equipment. The PDU has an Ethernet connection, an external connection for two environmental probes and two connections for linking PDUs together. You can enter the IP address using the local display for quick attachment to the network. Then, access the PDU remotely using a web browser for detailed measurements and to set upper and lower threshold alarms for power, temperature and humidity. Link up to 20 PDUs together to share a single Ethernet connection and IP address. The web browser lets you easily click between linked PDUs and any alarms are summarized on a separate tab. You can also forward email alarm notifications to staff and log data and events to keep a record of power use and alarms.
The PDU features a low profile design, has universal tool-less mounting and can be confidently deployed in cabinets with CPI vertical exhaust ducts or in hot aisle containment applications in ambient air temperatures up to 149°F (65°C).