Quick tech specs
- Single-Phase Metered/ATS Rackmount PDU w/ 19 Outlets and 2 10ft cords
- Single phase 5kW 30A 208V Auto Transfer Switch PDU
- Separate primary and secondary inputs (1-5ms switchover time
- Front panel digital display with LED indicators
- PDU/ Power Distribution Unit/ Horizontal PDU/ PDU Strip/ rack pdu/ ATS pdu/ pdus/ metered pdu/ data center pdu/ network pdu
- Enables redundant-power for single-corded network devices
- 2 L6-30P inputs; 19 outlets (16 C13/2 C19/1 L6-30R)
Know your gear
PDUMH30HVAT Metered ATS / Auto-Transfer Switch offers 208/240V 30A dual-input power distribution and visual current metering in a 2U horizontal rackmount installation format. Set of two NEMA L6-30P line cords enable separate primary and secondary input connections. Includes 19 built-in outputs (16 C13, 2 C19 and 1 L6-30R). Digital current metering with push-button display control tracks output power consumption in 4 segments: Bank 1 (9 upper C13 and C19 outlets), Bank 2 (9 lower C13 and C19 outlets), L6-30R (single outlet) and total PDU output. Supports 2U installation in 2 or 4 post racks, with additional support for wall-mount and under-counter placement.
Tripp Lite's Metered ATS / Auto-Transfer Switch PDU Systems provide redundant-power and hot-swappable UPS options for network and server applications powered by a single input line cord. Separate PRIMARY and SECONDARY input line cords enable a redundant connection to two separate mains circuits. ATS systems will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within 2-6 milliseconds. ATS functionality is supported by any two compatible power sources, regardless of phase angle, to offer support for a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant dual-UPS protection when each cord is connected to a separate UPS system. In a dual-UPS configuration, the primary input cable must be supported by a full time sine wave online UPS. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LEDs display primary and secondary power availability. Additional LEDs identify the displayed load segment reported by the digital current display.
Tripp Lite's Metered ATS / Auto-Transfer Switch PDU Systems provide redundant-power and hot-swappable UPS options for network and server applications powered by a single input line cord. Separate PRIMARY and SECONDARY input line cords enable a redundant connection to two separate mains circuits. ATS systems will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within 2-6 milliseconds. ATS functionality is supported by any two compatible power sources, regardless of phase angle, to offer support for a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant dual-UPS protection when each cord is connected to a separate UPS system. In a dual-UPS configuration, the primary input cable must be supported by a full time sine wave online UPS. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LEDs display primary and secondary power availability. Additional LEDs identify the displayed load segment reported by the digital current display.
Add to Compare