Quick tech specs
- 2.9kW single-phase ATS/Switched PDU 120V 2U horizontal w/ 25 outlets and two 10ft cords
- Enables redundant A/B power option for single-corded network devices
- 24 NEMA 5-15/20R and 1 L5-30R; 2 L5-30P inputs 10ft cords
- PDU/ Power Distribution Unit/ PDU Strip/ Switched PDU/ rack pdu/ pdus/ datacenter pdu/ network pdu/ Horizontal PDU/ ATS PDU
- Separate primary/secondary inputs connect to any two compatible power sources
- Network interface enables remote control and monitoring
Know your gear
PDUMH30ATNET 2U horizontal rackmount Auto Transfer Switch / ATS offers 30A 120V multi-outlet power distribution with dual input connections, individually switched outlets, built-in network interface and digital current metering. Includes separate L5-30P primary and secondary input cords and 25 switched output receptacles. Built-in network interface enables remote SNMP/Web monitoring and control. Remotely displays status of input power, load level and outlet power status via secure network or web browser interface. Supports optional environmental and contact-closure sensor options. Offers programmable or real-time individual outlet control to power on, off, or cycle AC output to regain control of locked-up servers and other network devices. Tripp Lite Automatic Transfer Switch / ATS systems enable advanced redundant power configurations for network equipment with a single AC input connection. Separate primary and secondary cables support connection to any two compatible power sources. ATS systems normally maintain continuous output to all outlets as derived from the primary input. If the primary power source becomes unstable or fails altogether in relation to the secondary input, the ATS will automatically switch over to the secondary power source until the primary input is restored and stable. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle to offer support for a variety of unique redundant power applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave online UPS. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LEDs display primary and secondary power availability.
Add to Compare